Application of PM5 Gen3 in Measuring Wood Surface Coatings and Solutions to Key Challenges

2026-02-04 18:23:38 www.yushindt.com

In fields such as wood processing, furniture manufacturing, and the restoration of historic wooden structures, precise measurement of both wood thickness and surface coating thickness is essential. Accurate control of wood thickness directly affects structural stability and material utilization, while the thickness of surface coatings—such as paint, varnish, and protective finishes—has a direct impact on appearance, durability, and overall protection.

Ultrasonic thickness gauges, with their non-destructive nature, high accuracy, and ease of operation, have become an ideal tool for these measurement applications. However, measuring coatings on wood has long faced various technical challenges. 

This article will analyze these difficulties in depth and present detailed, targeted solutions to help relevant industries achieve efficient and precise thickness measurement.

 YUSHI INSTRUMENTS


1. Basic Principle of Ultrasonic Thickness Measurement

An ultrasonic thickness gauge operates based on the principle of ultrasonic pulse-echo measurement. The probe emits high-frequency ultrasonic pulses into the test material (wood or coating). As the ultrasound travels through the material, it reflects at the interfaces between different media—for example, the boundary between the coating and the wood, or between the wood and the air.

The probe receives the reflected echo signals, and the instrument calculates the material thickness using the ultrasound velocity and travel time, following the formula:

Thickness = (Ultrasonic Velocity × Travel Time) / 2
(The division by 2 accounts for the round-trip travel of the ultrasonic wave.)


2.Core Challenges in Measuring Coatings on Wood

Measuring Coatings on Wood

In practical applications, when using an ultrasonic thickness gauge to measure coating thickness on wood, two major challenges are commonly encountered. These issues significantly affect both measurement accuracy and efficiency:

  • Small Acoustic Impedance Difference Between the Coating and Wood

Coatings (such as polyurethane paint or nitrocellulose paint) and wood (such as pine or oak) have similar densities and ultrasonic velocities. As a result, the ultrasonic reflection signal at the interface between the coating and the wood is very weak.
This makes it difficult for the instrument to clearly distinguish among the reflection from the top surface of the coating, the refection from the coating–wood interface, and the reflection from the bottom surface of the wood.

Consequently, the instrument may mistake the combined thickness of the coating and wood as the wood thickness alone, or it may fail to accurately identify the coating thickness.

  • Interference Caused by the Complex Nature of Wood

Wood is an anisotropic material. Its grain direction (longitudinal, radial, or tangential), moisture content, and density variations all influence the propagation velocity and path of ultrasonic waves.


3. Solutions to Measurement Challenges for Coatings on Wood

To address the difficulties mentioned above, we have developed a comprehensive set of solutions through technological innovation and methodological optimization, including instrument upgrades and improved measurement techniques. These solutions effectively overcome the challenges of measuring coatings on wood and enable high-precision thickness measurement.

Measure Wood Coating

  • Using High-Frequency Probes to Enhance Signal Identification

To address the challenges of thin coatings and weak reflection signals, the probe frequency is increased from the conventional 2–5 MHz to 10–20 MHz.
High-frequency ultrasound has a shorter wavelength, enabling it to more accurately capture the interface echoes of thin coatings. This allows the instrument to clearly distinguish the reflections from the top surface of the coating, the coating–wood interface, and the bottom surface of the wood.

  • Verifying Coating Echoes for Accurate Thickness Calculation

Confirming that the detected echoes are correct:
A comparative method is used for verification. First, measure a piece of wood without any coating and observe the instrument’s echo display (as shown in Figure 1). Only the delay line echo is visible, with no coating-related echo.

Next, measure the wood with the coating and observe the new echo pattern (as shown in Figure 2). Both the delay line echo and the coating echo can be clearly identified.

Once the acoustic velocity is properly set, the instrument displays a numerical reading, which corresponds to the coating thickness.

Wood coating thickness gauge YUSHI PM5 Gen3

wood paint thickness measurement


4. Testing Conclusion

Ultrasonic thickness measurement of coatings on wood has long been a technical challenge in the industry. The core difficulties arise from factors such as the thinness of the coating, the complexity of the material, and the difficulty of identifying signals. By using higher-frequency probes and further optimized software settings, we have successfully overcome these obstacles, achieving high-precision and non-destructive measurement of coating thickness on wood.

The PM5 Gen3 is not only suitable for measuring coatings on wood but is also capable of measuring coatings on materials such as concrete, glass, and fiberglass.

If you encounter any thickness-measurement challenges — Feel free to reach out YUSHI INSTRUMENTS!